High Level Requirement:
As a sequence from the Design (US 410)
Send Alarm : only when RAN state is changed from Connected to Not Connected (Disconnected, Shutdown, Shutting down) - This is SET ALARM and vice averse - This is CLEAR ALARM.
I have no knowledge how the Alarm Library is working, I expect it to have 2 methods - Set (Set Alarm) and Clear (Clear Alarm), and with the right object (RAN Name, Connection Status).
Acceptance
The following is sequential events, one after other:
- Setup Request for New RAN. See no call to Alarm Library.
- Lost Connection from this RAN. See Alarm is SET
- Setup Request from this RAN. See Alarm is CLEAR.
- Setup Request for New RAN. See no call to Alarm Library.
- Shut Down to all. See Alarm is SET only once (moving to Shutting Down) and no more.
- Gain connection again and lost it. Now Shut Down to all. See no call to Alarm Library.
- Gain connection again. E2T Initialize. See Alarm is SET
- Gain connection again and lost it. E2T Initialize. See no call to Alarm Library.
- Gain connection again. KA discover E2T is dead. See Alarm is SET
- Gain connection again and lost it. KA discover E2T is dead. See no call to Alarm Library