Alarm interface as per standard WAS Bronze O1 flow does not carry over SDNC - O1 Mediator connection

XMLWordPrintable

      During testing for Bronze O1 flow (https://wiki.o-ran-sc.org/pages/viewpage.action?pageId=14221844), the Netconf connection between OAM (SDNC) and NearRTRIC (O1 Mediator) is established and O1 advertises one of its capabilities as:
      {
      "capability-origin": "device-advertised",
      "capability": "(urn:o-ran:ric:alarm:1.0?revision=2020-01-29)o-ran-sc-ric-alarm-v1"
      }. However, when OAM queries for alarms (restconf/operational/network-topology:network-topology/topology/topology-netconf/node/near-rt-ric-01/yang-ext:mount/o-ran-sc-ric-alarm-v1:ric/alarms), it reports error: "error-message": "Request could not be completed because the relevant data model content does not exist".