Uploaded image for project: 'Near Realtime RAN Intelligent Controller'
  1. Near Realtime RAN Intelligent Controller
  2. RIC-1026

E2T to disconnect SCTP associations that do not properly establish E2Setup

XMLWordPrintable

    • Icon: Epic Epic
    • Resolution: Unresolved
    • Icon: Medium Medium
    • ZZZ_future
    • None
    • e2
    • None
    • E2T to disconnect SCTP associations that do not properly establish E2Setup

      we tear down the SCTP association if

      (1) E2 session not established yet and
      (2) No E2 Setup request received for A seconds, A by default set to 120 seconds

      This would cover the case that there’s a hanging SCTP association that is generally fine,
      but on application level something went wrong and the E2 Setup is not working properly. Note
      that this situation is not recovered by SCTP-level timeouts.

        No reviews matched the request. Check your Options in the drop-down menu of this sections header.

            dhirajverma dhiraj verma
            czichy Thoralf Czichy
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

              Created:
              Updated: